1. Summary
The hydraulic butterfly valve test bench of model YFS-DL is used to perform shell test and seat test of butterfly valves. As for the way of loading and clamping of the valve to be tested, the test bench adopts the way of pulling downwards of the clamping jaw. As for the form of configuration, the test bench can also be designed into two types, unitary type, that is, one hydraulic station controls one workbench, and set type, that is, one hydraulic station controls two workbenches. The appropriate type of test bench will be selected, designed and manufactured according to the customers′ requirements of testing pressure range.

2. Technical Parameters
Model & Specification |
Type |
Testing Range |
Diameter & Quantity of Clamping Oil Cylinder |
Spacing Between Jaw & Working Plate(mm) |
Max.Clamping Force(t) |
Motor of Oil Pump(6 Poles) |
Outine Dimensions(L×W×H) |
YFS-DL200 |
Unitary |
DN50-200 |
φ100×3 |
200-400 |
50 |
2.2KW |
1000×2000×1600 |
YFS-DL300 |
Unitary |
DN80-300 |
φ110×3 |
220-470 |
60 |
2.2KW |
1100×2100×1600 |
YFS-DL400 |
Unitary |
DN150-400 |
φ120×4 |
260-540 |
90 |
3.0KW |
1180×2200×1600 |
YFS-DL500 |
Unitary |
DN200-500 |
φ140×4 |
290-590 |
130 |
3.0KW |
1250×2300×1600 |
YFS-DL600 |
Unitary |
DN250-600 |
φ150×4 |
310-630 |
150 |
3.0KW |
1350×2500×1600 |
YFS-DL800 |
Unitary |
DN350-800 |
φ160×4 |
340-730 |
170 |
5.5KW |
1500×2800×1600 |
YFS-DL1000 |
Unitary |
DN500-1000 |
φ160×6 |
380-880 |
250 |
5.5KW |
1800×3000×1700 |
YFS-DL1200 |
Separate |
DN600-1200 |
φ180×6 |
410-960 |
350 |
5.5KW |
2100×3400×1700 |
YFS-DL1600 |
Separate |
DN800-1600 |
φ200×6 |
550-1200 |
420 |
5.5KW |
2600×4000×1700 |
3. Pressure Check List
Model YFS-DL200
Nominal Diameter |
Nominal Pressure MPa/class |
1.0 |
1.6 |
2.5 |
4.0 |
6.4 |
|
|
150 |
300 |
400 |
Pressure of Hydraulic Station |
in |
mm |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
2″ |
DN50 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
21/2″ |
DN65 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
3″ |
DN80 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
4″ |
DN100 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
5″ |
DN125 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
6″ |
DN150 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
8″ |
DN200 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
Model YFS-DL300
Nominal Diameter |
Nominal Pressure MPa/class |
1.0 |
1.6 |
2.5 |
4.0 |
6.4 |
|
|
150 |
300 |
400 |
Pressure of Hydraulic Station |
in |
mm |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
3″ |
DN80 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
4″ |
DN100 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
5″ |
DN125 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
6″ |
DN150 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
8″ |
DN200 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
10″ |
DN250 |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
12″ |
DN300 |
● |
● |
● |
● |
● |
● |
|
|
|
|
PN-denotes the pressure of the oil cylinder when performing seat test ;PS-denotes the pressure of the oil cylinder when performing shell test
Model YFS-DL400
Nominal Diameter |
Nominal Pressure MPa/class |
0.6 |
1.0 |
1.6 |
2.5 |
4.0 |
6.4 |
|
|
|
150 |
300 |
400 |
Pressure of Hydraulic Station |
in |
mm |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
6″ |
DN150 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
8″ |
DN200 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
10″ |
DN250 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
12″ |
DN300 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
14″ |
DN350 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
16″ |
DN400 |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
Model YFS-DL500
Nominal Diameter |
Nominal Pressure MPa/class |
0.6 |
1.0 |
1.6 |
2.5 |
4.0 |
6.4 |
|
|
|
150 |
300 |
400 |
Pressure of Hydraulic Station |
in |
mm |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
8″ |
DN200 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
10″ |
DN250 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
12″ |
DN300 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
14″ |
DN350 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
16″ |
DN400 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
18″ |
DN450 |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
20″ |
DN500 |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
Model YFS-DL600
Nominal Diameter |
Nominal Pressure MPa/class |
0.6 |
1.0 |
1.6 |
2.5 |
4.0 |
6.4 |
|
|
|
150 |
300 |
400 |
Pressure of Hydraulic Station |
in |
mm |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
10″ |
DN250 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
12″ |
DN300 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
14″ |
DN350 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
16″ |
DN400 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
18″ |
DN450 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
20″ |
DN500 |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
24″ |
DN600 |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
| PN-denotes the pressure of the oil cylinder when performing seat test ;PS-denotes the pressure of the oil cylinder when performing shell test
Model YFS-DL800
Nominal Diameter |
Nominal Pressure MPa/class |
0.6 |
1.0 |
1.6 |
2.5 |
4.0 |
|
|
|
150 |
300 |
Pressure of Hydraulic Station |
in |
mm |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
14″ |
DN350 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
16″ |
DN400 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
18″ |
DN450 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
20″ |
DN500 |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
24″ |
DN600 |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
28″ |
DN700 |
● |
● |
● |
● |
● |
● |
|
|
|
|
32″ |
DN800 |
● |
● |
● |
● |
● |
● |
|
|
|
|
Model YFS-DL1000
Nominal Diameter |
Nominal Pressure MPa/class |
0.6 |
1.0 |
1.6 |
2.5 |
4.0 |
|
|
|
150 |
300 |
Pressure of Hydraulic Station |
in |
mm |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
20″ |
DN500 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
24″ |
DN600 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
28″ |
DN700 |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
32″ |
DN800 |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
36″ |
DN900 |
● |
● |
● |
● |
● |
● |
|
|
|
|
40″ |
DN1000 |
● |
● |
● |
● |
● |
● |
|
|
|
|
Model YFS-DL1200
Nominal Diameter |
Nominal Pressure MPa/class |
0.6 |
1.0 |
1.6 |
2.5 |
4.0 |
|
|
|
150 |
300 |
Pressure of Hydraulic Station |
in |
mm |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
24″ |
DN600 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
28″ |
DN700 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
32″ |
DN800 |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
36″ |
DN900 |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
40″ |
DN1000 |
● |
● |
● |
● |
● |
● |
|
|
|
|
48″ |
DN1200 |
● |
● |
● |
● |
● |
● |
|
|
|
|
Model YFS-DL1600
Nominal Diameter |
Nominal Pressure MPa/class |
0.6 |
1.0 |
1.6 |
2.5 |
|
|
|
150 |
Pressure of Hydraulic Station |
in |
mm |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
32″ |
DN800 |
● |
● |
● |
● |
● |
● |
● |
● |
36″ |
DN900 |
● |
● |
● |
● |
● |
● |
● |
● |
40″ |
DN1000 |
● |
● |
● |
● |
● |
● |
● |
● |
48″ |
DN1200 |
● |
● |
● |
● |
● |
● |
|
|
56″ |
DN1400 |
● |
● |
● |
● |
|
|
|
|
64″ |
DN1600 |
● |
● |
● |
● |
|
|
|
|
PN-denotes the pressure of the oil cylinder when performing seat test ;PS-denotes the pressure of the oil cylinder when performing shell test
|